The BN Micro Computed Tomography Center, located on the Incubation Center for Medical Equipment and Devices (ICMED), houses LOTUS systems with the versatility to scan all kind of samples ( e.g. oil core plugs, bone and teeth samples, etc.) at high resolution. Scan reconstruction and analysis software can be used on the LOTUS scanning systems or they can be installed on individual laboratory workstations. full-service scanning is available.

LOTUS-NDT and LOTUS-inVivo systems are available.

Equipment Specifications:

LOTUS-NDT :The diameter of objects to be scanned must not exceed 2 inch. the length of object must not exceed 120 mm.

LOTUS-inVivo : The diameter of objects to be scanned must not exceed 80 mm. the length of object must not exceed 120 mm.

LOTUS-NDT: 3 µm nominal / 1 µm smallest pixel size.

LOTUS-inVivo: 30 µm nominal / 10 µm smallest pixel size.

All LOTUS systems adjust the source to camera distance to minimize scan time for each selected magnification (1-240 minutes, depending on resolution and pixels used)

LOTUS-NDT: Sealed micro-focus X-ray tube, air-cooled, <5 µm spot size @40 W, Wide range kVp, 0-600 µA

LOTUS-inVivo: Sealed micro-focus X-ray tube, air-cooled, <5 µm spot size @8 W, 45-90 kV, 0-200 µA

3 MP 16-bit digital camera.

LOTUS Workstation with 16 Cores AMD Ryzen CPU, NVIDIA Geforce 4 GB GPU, 128 GB RAM

Multi-Threaded and Parallel GPU-based Available.

Convolution with filtered back-projection for cone-beam (Feldkamp)

Pricing:
LOTUS-NDT Micro-CT Scan Services:
500,000 Tomans per hour
or
50 $ per hour
 
****************************************************************
LOTUS-inVivo Micro-CT Scan Services:
450,000 Tomans per hour
or
45 $ per hour
Analysis Level 1
* basic analysis, e.g. pore-size distribution calculations from generated 3D model.
* analysis of 1 parameter.


200,000 Tomans per hour
or
20 $ per hour

*****************************************************************************************************************************************
Analysis Level 2
* intermediate analyses, e.g. permeability, effective pore-size distribution calculations from generated 3D model.
* analyses of 2 parameters.


300,000 Tomans per hour
or
30 $ per hour

*****************************************************************************************************************************************
Analysis Level 3
* advanced analyses, e.g. 3D pore network modeling and pore shape analyses, Crack analysis and Impurity characterization.
* providing analyses of more than 3 parameters.

400,000 Tomans per hour
or
40 $ per hour

For submitting an imaging task, fill the imaging request form.

If you need free Micro-CT sample datasets of any objects, feel free to contact us. We’ll provide you the required sample dataset as soon as possible.

For more information Contact Us.